Waterless Trap Seals for Every Drain Size. Shop All Products
North Dakota

North Dakota plumbing code: which edition applies and what it requires

North Dakota uses the Uniform Plumbing Code (UPC). The current edition is 2018 UPC, effective 2020-04-01, adopted by the North Dakota State Plumbing Board and enforced by the local authority having jurisdiction (AHJ).

North Dakota plumbing code at a glance

Adopted code2018 North Dakota Plumbing Code (2018 UPC), NDAC 62-03.1
Code familyUPC
Current edition2018 UPC
Effective date2020-04-01
Adopting authorityNorth Dakota State Plumbing Board
Trap seal protectionAddressed in Chapter 10 (Traps); barrier-type floor drain devices conform to ASSE 1072 (UPC Section 1007).
Waterless trap seal acceptanceThe UPC recognizes barrier-type floor drain trap seal protection devices (ASSE 1072) as a trap seal protection method (UPC Section 1007). Whether one serves in lieu of a trap primer is an AHJ decision. Confirm with the AHJ.
Local amendments / enforcementStatewide; ND adopts UPC Ch 10 in full, no amendment to 1007

This page summarizes how North Dakota adopts and applies its plumbing code. It is a reference for planning, not legal or code-compliance advice. Always confirm current requirements with the adopted code text and your local AHJ.

Does North Dakota use the IPC or the UPC?

North Dakota uses the UPC. Its plumbing code is based on the Uniform Plumbing Code published by IAPMO, not the International Plumbing Code.

The adopted code is the 2018 North Dakota Plumbing Code (2018 UPC), NDAC 62-03.1, which uses the UPC as its base with state amendments. North Dakota is one of the states in the UPC family.

What edition of the plumbing code does North Dakota use, and when did it take effect?

North Dakota's current edition is 2018 UPC, effective 2020-04-01, adopted by the North Dakota State Plumbing Board.

Codes update on a multi-year cycle, and an adopted-but-not-yet-effective edition can circulate near a changeover. Confirm which edition your project falls under by its permit date and your local jurisdiction.

How do local jurisdictions affect North Dakota's plumbing code?

North Dakota's code is the statewide baseline, but local jurisdictions enforce it and may add amendments. The local authority having jurisdiction (AHJ) resolves how it applies to a specific project.

Statewide; ND adopts UPC Ch 10 in full, no amendment to 1007. Confirm any local amendments and the accepted trap-seal methods with your city or county building department before relying on a provision.

What does the plumbing code require for floor drains and trap seals?

Floor drains rely on a trap, and the code requires that trap seal to be maintained. A floor drain that receives little water can lose its seal to evaporation, which opens a path for sewer gas, odors, and pests.

To prevent that, codes recognize trap seal protection methods. The two most common are a trap seal primer (which adds water to the trap) and a barrier-type floor drain trap seal protection device (which provides a mechanical seal). The right approach depends on the drain, the space, and the AHJ.

In North Dakota, the requirement is in the traps chapter of the adopted code (UPC Section 1007). The UPC recognizes a barrier-type device conforming to ASSE 1072 as a trap seal protection method; whether one stands in for a trap primer is decided by the AHJ.

Are barrier-type (ASSE 1072) trap seals allowed under North Dakota's code?

Yes, as a recognized method. The UPC recognizes barrier-type floor drain trap seal protection devices conforming to ASSE 1072 (UPC Section 1007). Whether a barrier device serves in lieu of a trap primer is a decision for the AHJ under the UPC's trap-seal requirement.

Note that a restrictive "shall not be used in lieu of" clause some references show is an Oregon amendment, not part of the base UPC, so it does not apply here. As with any device, acceptance for a specific installation rests with the local AHJ.

Do I need a permit to add a floor-drain trap seal in North Dakota?

Usually not for the device itself, but always confirm with your local authority having jurisdiction.

A drop-in barrier-type trap seal device generally does not require a plumbing permit because it does not alter any piping, similar to changing a drain grate. On new construction or an already-permitted renovation, include it in the plumbing specifications.

In North Dakota, plumbing permits and inspections run through North Dakota State Plumbing Board and the local building department, and a licensed plumber pulls permits for plumbing work. Licensing rules and reciprocity vary, so confirm them with the authority or your local jurisdiction.

Where can I read North Dakota's plumbing code?

The adopting authority and code text are linked below. Always confirm current requirements against the adopted code and your local AHJ.

Where Green Drain fits. Green Drain is a barrier-type waterless trap seal for floor drains. It is cUPC listed through IAPMO (File No. 9301) and tested to ASSE 1072-2020, the standard this code references for these devices. For a floor drain at risk of a dry trap, it is one code-recognized way to keep the trap seal intact, and it works alongside the existing P-trap rather than replacing it.

Acceptance for any specific installation rests with your local AHJ. See Green Drain certifications for listing details, or browse waterless trap seals by drain size.

Protecting floor drains in North Dakota?

Find the right waterless trap seal for your drain size, or talk to our team about a project.